Functional Imaging of Hepatic Masses Using Computed Tomography
Hiroshima Journal of Medical Sciences 36 巻 1 号
113-120 頁
1987-03 発行
アクセス数 : 286 件
ダウンロード数 : 50 件
今月のアクセス数 : 2 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00049969
ファイル情報(添付) |
HiroshimaJMedSci_36_113.pdf
8.18 MB
種類 :
全文
|
タイトル ( eng ) |
Functional Imaging of Hepatic Masses Using Computed Tomography
|
作成者 |
FUJIKAWA Koichi
YAMANE Kosuke
NAKANISHI Tadashi
KATSUTA Shizutomo
|
収録物名 |
Hiroshima Journal of Medical Sciences
|
巻 | 36 |
号 | 1 |
開始ページ | 113 |
終了ページ | 120 |
収録物識別子 |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
抄録 |
In order to assess the usefulness of CT functional images, twenty one cases with liver masses were studied. We tried to minimize the motion artifacts by immobilizing the patients with a girdle in performing dynamic CT scans, and by discarding some of the segmented images with serious artifacts before constructing functional images. The qualities of images obtained were considered satisfactory. Of the several transit parameters obtained from the dynamic CT scans, we found the first moment (Ml) to be most useful and the effectiveness of Ml-functional images were studied. In all cases with hepatocellular carcinomas (12 cases) and intrahepatic cholangiocarcinomas (2 cases), the Ml-functional images showed the viable portions of tumors as accumulations of dark pixels reflecting rapid transit times due to arterial blood supply. In three cases with hepatic cavernous hemangiomas, the lesions were represented as bright areas with a well-defined border. In two cases with hepatic abscesses, the Ml-functional images suggested the presence of hyperemia in the surrounding tissue as demonstrated by bright pixels around the lesions.
CT functional imaging was proved to be useful for evaluating the circulatory dynamics of contrast material and the differential diagnosis of liver tumors when conventional or dynamic CT studies failed to provide enough information. This technique enabled overall analysis of time-density curves for the entire plane of an image semiautomatically and without the subjective maneuver of setting ROI's (regions of interest). |
著者キーワード |
Functional imaging
Hepatic tumor
Computed tomography
CT data processing
|
NDC分類 |
医学 [ 490 ]
|
言語 |
英語
|
資源タイプ | 紀要論文 |
出版者 |
Hiroshima University School of Medicine
|
発行日 | 1987-03 |
出版タイプ | Version of Record(出版社版。早期公開を含む) |
アクセス権 | オープンアクセス |
収録物識別子 |
[ISSN] 0018-2052
[NCID] AA00664312
[PMID] 3583800
|