Rupture of Donor Ascending Aorta following Heart Transplantation

アクセス数 : 1068
ダウンロード数 : 164

今月のアクセス数 : 16
今月のダウンロード数 : 5
ファイル情報(添付)
HiroshimaJMedSci_43_73.pdf 396 KB 種類 : 全文
タイトル ( eng )
Rupture of Donor Ascending Aorta following Heart Transplantation
作成者
Wada Seishi
Mitsui Norimasa
Mukai Shogo
Matsuura Yuichiro
Roques Xavier F.
Laborde Marie N.
Yssartier Françoise
Baudet Eugène M.
収録物名
Hiroshima Journal of Medical Sciences
43
2
開始ページ 73
終了ページ 76
収録物識別子
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
抄録
Among 81 patients who underwent orthotopic heart transplantation between July 1986 and December 1990, we found rupture of the donor ascending aorta in three patients, all with severe ventricular dysfunction secondary to aortic valvular disease. The mechanism for this may be compliance mismatch between the recipient ascending aorta and the donor ascending aorta. This situation is a unique complication in heart transplantation for the recipients who have severe athero-sclerotic changes in the systemic aortic wall, especially for those with valvular diseases caused by calcification.
著者キーワード
Heart transplantation
Aortic rupture
Compliance mismatch
NDC分類
医学 [ 490 ]
言語
英語
資源タイプ 紀要論文
出版者
Hiroshima University Medical Press
発行日 1994-06
出版タイプ Version of Record(出版社版。早期公開を含む)
アクセス権 オープンアクセス
収録物識別子
[ISSN] 0018-2052
[NCID] AA00664312