Assessment of a New Silicone Tri-leaflet Valve Seamlessly Assembled with Blood Chamber for a Low-cost Ventricular Assist Device
Hiroshima Journal of Medical Sciences 47 巻 2 号
47-55 頁
1998-06 発行
アクセス数 : 1150 件
ダウンロード数 : 150 件
今月のアクセス数 : 2 件
今月のダウンロード数 : 1 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00037792
ファイル情報(添付) |
HiroshimaJMedSci_47_47.pdf
1.41 MB
種類 :
全文
|
タイトル ( eng ) |
Assessment of a New Silicone Tri-leaflet Valve Seamlessly Assembled with Blood Chamber for a Low-cost Ventricular Assist Device
|
作成者 |
Hirai Shinji
Fukunaga Shintaro
Sueshiro Masafumi
Watari Masanobu
Matsuura Yuichiro
|
収録物名 |
Hiroshima Journal of Medical Sciences
|
巻 | 47 |
号 | 2 |
開始ページ | 47 |
終了ページ | 55 |
収録物識別子 |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
抄録 |
We have developed a practical, low-cost ventricular assist device (VAD) comprising a newly designed blood chamber with a silicone lenticular sac and two silicone tri-leaflet valves (STV), made en bloc. This new VAD is seamless, can be made cost-effectively and assembled with the blood chamber and valve as one body. This novel design should reduce the incident of thrombus formation because of the absence of a junction at the connecting ring and because of the use of flexible silicone materials which have both antithrombogenecity and biocompatibility. In in vitro hemodynamics testing, a batch of 3 consecutively manufactured V ADs with STV s underwent hydrodynamic functional testing. These showed less regurgitation, a lower value of water hammer phenomenon, and a slightly greater pressure gradient across the valves than a mechanical valve (MV) [Björk-Shiley monostrut valve]. The flow and pulsatile efficiency were adequate and similar to that of a VAD with MVs. In in vitro durability and hemolysis tests, a V AD with STV functioned well for 54 days and showed similar hemolytic profiles to a V AD with MVs. In an in vivo acute experiment using an adult sheep, our device was promblem-free providing sufficient output as a left ventricular assist device (LVAD). Although it will be necessary to decrease the pressure gradient across this STV in the future, our device showed efficient performance as a practical and cost-effective V AD for short term use.
|
著者キーワード |
Silicone tri-leaflet valve
Silicone blood chamber
Ventricular assist device
|
内容記述 |
This work was supported in part by the Tsuchiya Foundation and by a Research Grant for Cardiovascular Diseases (7A-1) from the Ministry of Health and Welfare, Japan
|
NDC分類 |
医学 [ 490 ]
|
言語 |
英語
|
資源タイプ | 紀要論文 |
出版者 |
Hiroshima University Medical Press
|
発行日 | 1998-06 |
出版タイプ | Version of Record(出版社版。早期公開を含む) |
アクセス権 | オープンアクセス |
収録物識別子 |
[ISSN] 0018-2052
[NCID] AA00664312
|