Use of potassium-form cation-exchange resin as a conductimetric enhancer in ion-exclusion chromatography of aliphatic carboxylic acids

Talanta 79 巻 4 号 1026-1030 頁 2009-09-15 発行
アクセス数 : 742
ダウンロード数 : 186

今月のアクセス数 : 1
今月のダウンロード数 : 1
ファイル情報(添付)
Talanta_79_1026.pdf 198 KB 種類 : 全文
タイトル ( eng )
Use of potassium-form cation-exchange resin as a conductimetric enhancer in ion-exclusion chromatography of aliphatic carboxylic acids
作成者
Iwata Tomotaka
Mori Masanobu
Itabashi Hideyuki
収録物名
Talanta
79
4
開始ページ 1026
終了ページ 1030
抄録
In this study, a cation-exchange resin (CEX) of the W-form, i.e., an enhancer resin, is used as a postcolumn conductimetric enhancer in the ion-exclusion chromatography of aliphatic carboxylic acids. The enhancer resin is filled in the switching valve of an ion chromatograph; this valve is usually used as a suppressor valve in ion-exchange chromatography. An aliphatic carboxylic acid (e.g.,CH3COOH) separated by a weakly acidic CEX column of the H+-form converts into that of the K+-form (e.g., CH3COCK) by passing through the enhancer resin. In contrast, the background conductivity decreases because a strong acid (e.g., HNO3) with a higher conductimetric response in an eluent converts into a salt (e.g., KNO3 with a lower conductimetric response. Since the pH of the eluent containing the resin enhancer increases from 3.27 to 5.85, the enhancer accelerates the dissociations of analyte acids. Consequently, peak heights and peak areas of aliphatic carboxylic acids (e.g., acetic acid, propionic acid, butyric acid, and valeric acid) with the enhancer resin are 6.3-8.0 times higher and 7.2-9.2 times larger, respectively, than those without the enhancer resin. Calibrations of peak areas for injected analytes are linear in the concentration range of 0.01-1.0 mM.The detection limits (signal-to-noise ratio = 3) range from 0.10 mu M to 0.39 mu M in this system, as opposed to those in the range of 0.24-7.1 mu M in the separation column alone. The developed system is successfully applied to the determination of aliphatic carboxylic acids in a chicken droppings sample.
著者キーワード
Ion-exclusion chromatography
Conductimetric enhancer
Cation exchange
Aliphatic carboxylic acids
NDC分類
化学 [ 430 ]
言語
英語
資源タイプ 学術雑誌論文
出版者
Elsevier Science BV
発行日 2009-09-15
権利情報
Copyright (c) 2009 Elsevier B. V.
出版タイプ Author’s Original(十分な品質であるとして、著者から正式な査読に提出される版)
アクセス権 オープンアクセス
収録物識別子
[ISSN] 0039-9140
[DOI] 10.1016/j.talanta.2009.03.042
[NCID] AA00856594