Use of potassium-form cation-exchange resin as a conductimetric enhancer in ion-exclusion chromatography of aliphatic carboxylic acids

Talanta Volume 79 Issue 4 Page 1026-1030 published_at 2009-09-15
アクセス数 : 742
ダウンロード数 : 186

今月のアクセス数 : 1
今月のダウンロード数 : 1
File
Talanta_79_1026.pdf 198 KB 種類 : fulltext
Title ( eng )
Use of potassium-form cation-exchange resin as a conductimetric enhancer in ion-exclusion chromatography of aliphatic carboxylic acids
Creator
Iwata Tomotaka
Mori Masanobu
Itabashi Hideyuki
Source Title
Talanta
Volume 79
Issue 4
Start Page 1026
End Page 1030
Abstract
In this study, a cation-exchange resin (CEX) of the W-form, i.e., an enhancer resin, is used as a postcolumn conductimetric enhancer in the ion-exclusion chromatography of aliphatic carboxylic acids. The enhancer resin is filled in the switching valve of an ion chromatograph; this valve is usually used as a suppressor valve in ion-exchange chromatography. An aliphatic carboxylic acid (e.g.,CH3COOH) separated by a weakly acidic CEX column of the H+-form converts into that of the K+-form (e.g., CH3COCK) by passing through the enhancer resin. In contrast, the background conductivity decreases because a strong acid (e.g., HNO3) with a higher conductimetric response in an eluent converts into a salt (e.g., KNO3 with a lower conductimetric response. Since the pH of the eluent containing the resin enhancer increases from 3.27 to 5.85, the enhancer accelerates the dissociations of analyte acids. Consequently, peak heights and peak areas of aliphatic carboxylic acids (e.g., acetic acid, propionic acid, butyric acid, and valeric acid) with the enhancer resin are 6.3-8.0 times higher and 7.2-9.2 times larger, respectively, than those without the enhancer resin. Calibrations of peak areas for injected analytes are linear in the concentration range of 0.01-1.0 mM.The detection limits (signal-to-noise ratio = 3) range from 0.10 mu M to 0.39 mu M in this system, as opposed to those in the range of 0.24-7.1 mu M in the separation column alone. The developed system is successfully applied to the determination of aliphatic carboxylic acids in a chicken droppings sample.
Keywords
Ion-exclusion chromatography
Conductimetric enhancer
Cation exchange
Aliphatic carboxylic acids
NDC
Chemistry [ 430 ]
Language
eng
Resource Type journal article
Publisher
Elsevier Science BV
Date of Issued 2009-09-15
Rights
Copyright (c) 2009 Elsevier B. V.
Publish Type Author’s Original
Access Rights open access
Source Identifier
[ISSN] 0039-9140
[DOI] 10.1016/j.talanta.2009.03.042
[NCID] AA00856594
[DOI] http://dx.doi.org/10.1016/j.talanta.2009.03.042