Comparison of astigmatism in three-year-old children with epiblepharon who underwent closer examination in a vision screening program
Hiroshima Journal of Medical Sciences 72 巻 1-2 号
5-9 頁
2023-06 発行
アクセス数 : 126 件
ダウンロード数 : 27 件
今月のアクセス数 : 6 件
今月のダウンロード数 : 1 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00054943
ファイル情報(添付) |
HiroshimaJMedSci_72_5.pdf
594 KB
種類 :
全文
|
タイトル ( eng ) |
Comparison of astigmatism in three-year-old children with epiblepharon who underwent closer examination in a vision screening program
|
作成者 |
KABURA Ryota
IWASAKI Rumi
FUKUDA Rikako
MATSUMOTO Kanon
FURUSHIMA Kyoka
TAKESHITA Tetsuji
|
収録物名 |
Hiroshima Journal of Medical Sciences
|
巻 | 72 |
号 | 1-2 |
開始ページ | 5 |
終了ページ | 9 |
ページ数 | 5 |
収録物識別子 |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
抄録 |
This study aimed to compare 3-year-old children with suspected astigmatism and refractive errors in a vision screening program (VSP) and those diagnosed with epiblepharon on closer examination (CE). In a population of 1,250 children in a VSP conducted between April 2014 and March 2021, 168 children received a CE rating, and 89 patients subsequently underwent CE. The handheld refractors used in VSP were SureSight® and Spot®VisionScreener (Welch Allyn). In CE, a 5 m Landolt C ring angular vision test and auto-ref/keratometer TONOREFTM II (NIDEK) was used for measurement in non-cycloplegia. Epiblepharon was diagnosed by an ophthalmologist using slit-lamp microscopy. The patients were divided into epiblepharon and non-epiblepharon groups for CE. VSP detected a cylindrical power of 1.65 ± 2.25 D and 0.86 ± 0.74 D, respectively, in the epiblepharon and without epiblepharon groups. CE detected an uncorrected visual acuity of 0.42 ± 0.46 and 0.16 ± 0.29 (logMAR), a corrected visual acuity of 0.22 ± 0.31 and 0.09 ± 0.24, a subjective cylindrical power of 0.65 ± 1.15 D and 0.23 ± 0.56 D, and corneal astigmatism of 1.97 ± 0.93 D and 1.45 ± 0.82 D in the epiblepharon and without epiblepharon groups, respectively; significant differences were observed for all parameters (p < 0.05). Among 3-year-old children with suspected amblyopia or refractive error not reaching the reference level, those with epiblepharon had more astigmatism than those without it. If a case of high astigmatism is found in the refractive test, an epiblepharon may be present.
|
著者キーワード |
Vision screening program
Epiblepharon
Astigmatism
|
内容記述 |
The findings were briefly presented in part as an oral presentation (#P-29) at the 62nd Annual Meeting of the Japanese Orthoptic Congress, Chiyoda-ku, Tokyo, Japan on November 20, 2021.
|
言語 |
英語
|
資源タイプ | 紀要論文 |
出版者 |
Hiroshima University Medical Press
|
発行日 | 2023-06 |
権利情報 |
Copyright (c) 2023 Hiroshima University Medical Press
|
出版タイプ | Version of Record(出版社版。早期公開を含む) |
アクセス権 | オープンアクセス |
収録物識別子 |
[DOI] https://doi.org/10.24811/hjms.72.1-2_5
~と同一である
|