Content-based CT image retrieval system using deep learning: Preliminary assessment of its accuracy for classifying lesion patterns and retrieving similar cases among patients with diffuse lung diseases
Hiroshima Journal of Medical Sciences 71 巻 1-2 号
9-22 頁
2022-06 発行
アクセス数 : 357 件
ダウンロード数 : 194 件
今月のアクセス数 : 2 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00052900
ファイル情報(添付) |
HiroshimaJMedSci_71_9.pdf
14.3 MB
種類 :
全文
|
タイトル ( eng ) |
Content-based CT image retrieval system using deep learning: Preliminary assessment of its accuracy for classifying lesion patterns and retrieving similar cases among patients with diffuse lung diseases
|
作成者 |
TERADA Hiroaki
HIGAKI Toru
TAKEBE Hiroaki
BABA Takayuki
MIYAZAKI Nobuhiro
MORIWAKI Yasutaka
SAKANE Hiroaki
FUKUMOTO Wataru
|
収録物名 |
Hiroshima Journal of Medical Sciences
|
巻 | 71 |
号 | 1-2 |
開始ページ | 9 |
終了ページ | 22 |
収録物識別子 |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
抄録 |
Practical image retrieval systems must fully use image databases. We investigated the accuracy of our content-based computer tomography (CT) image retrieval system (CB-CTIRS) for classifying lesion patterns and retrieving similar cases in patients with diffuse lung diseases. The study included 503 individuals, with 328 having diffuse lung disease and 175 having normal chest CT scans. Among the former, we randomly selected ten scans that revealed one of five specific patterns [consolidation, ground-glass opacity (GGO), emphysema, honeycombing, or micronodules: two cases each]. Two radiologists separated the squares into six categories (five abnormal patterns and one normal pattern) to create a reference standard. Subsequently, each square was entered into the CB-CTIRS, and the F-score used to classify squares was determined. Next, we selected 15 cases (three per pattern) among the 503 cases, which served as the query cases. Three other radiologists graded the similarity between the retrieved and query cases using a 5-point grading system, where grade 5 = similar in both the opacity pattern and distribution and 1 = different therein. The F-score was 0.71 for consolidation, 0.63 for GGO, 0.74 for emphysema, 0.61 for honeycombing, 0.15 for micronodules, and 0.67 for normal lung. All three radiologists assigned grade 4 or 5 to 67.7% of retrieved cases with consolidation, emphysema, or honeycombing, and grade 2 or 3 to 67.7% of the retrieved cases with GGO or micronodules. The retrieval accuracy of CB-CTIRS is satisfactory for consolidation, emphysema, and honeycombing but not for GGO or micronodules.
|
著者キーワード |
content-based image retrieval
diffuse lung disease
chest CT
|
言語 |
英語
|
資源タイプ | 紀要論文 |
出版者 |
Hiroshima University Medical Press
|
発行日 | 2022-06 |
権利情報 |
Copyright (c) 2022 Hiroshima University Medical Press
|
出版タイプ | Version of Record(出版社版。早期公開を含む) |
アクセス権 | オープンアクセス |
収録物識別子 |
[ISSN] 0018-2052
[ISSN] 2433-7668
[NCID] AA00664312
[DOI] 10.24811/hjms.71.1-2_9
|