A Modified Technique and Hemodynamic Evaluation of Heterotopic Cardiac Transplantation (Modified Ide Method)
Hiroshima Journal of Medical Sciences Volume 37 Issue 3
Page 103-107
published_at 1988-09
アクセス数 : 1104 件
ダウンロード数 : 133 件
今月のアクセス数 : 2 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00038153
File |
HiroshimaJMedSci_37_103.pdf
483 KB
種類 :
fulltext
|
Title ( eng ) |
A Modified Technique and Hemodynamic Evaluation of Heterotopic Cardiac Transplantation (Modified Ide Method)
|
Creator |
Matsuura Yuichiro
Matsushima Takeshi
Kajihara Hiroki
|
Source Title |
Hiroshima Journal of Medical Sciences
|
Volume | 37 |
Issue | 3 |
Start Page | 103 |
End Page | 107 |
Journal Identifire |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
Abstract |
A model of heterotopic cardiac transplantation which can evaluate the donor's heart function after preservation was developed. This model was modified from the working double heart model developed by Ide and his associates and is characterized by its ease in suturing in donor and recipient hearts.
Five mongrel dogs with the donor heart were observed hemodynamically from 3 to 6 hrs. Systemic circulation was successfully maintained with only the donor heart after ligation of the recipient aorta. This working double heart model consists of total L V bypass and partial RV bypass, and therefore permits estimation of L V function of the donor heart. |
Keywords |
Heterotopic cardiac transplantation
Myocardial preservation
|
NDC |
Medical sciences [ 490 ]
|
Language |
eng
|
Resource Type | departmental bulletin paper |
Publisher |
Hiroshima University Medical Press
|
Date of Issued | 1988-09 |
Publish Type | Version of Record |
Access Rights | open access |
Source Identifier |
[ISSN] 0018-2052
[NCID] AA00664312
[PMID] 3074071
|