Intraluminal Projection of Descending Thoracic Aorta and Intraaortic Balloon Pump Catheter Examined by Transesophageal Echocardiography in Patients Undergoing Coronary Artery Bypass Surgery
Hiroshima Journal of Medical Sciences 40 巻 4 号
119-126 頁
1991-12 発行
アクセス数 : 918 件
ダウンロード数 : 114 件
今月のアクセス数 : 0 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00038025
ファイル情報(添付) |
HiroshimaJMedSci_40_119.pdf
864 KB
種類 :
全文
|
タイトル ( eng ) |
Intraluminal Projection of Descending Thoracic Aorta and Intraaortic Balloon Pump Catheter Examined by Transesophageal Echocardiography in Patients Undergoing Coronary Artery Bypass Surgery
|
作成者 |
Orihashi Kazumasa
Oka Yasu
|
収録物名 |
Hiroshima Journal of Medical Sciences
|
巻 | 40 |
号 | 4 |
開始ページ | 119 |
終了ページ | 126 |
収録物識別子 |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
抄録 |
The thoracic descending aorta (DTA) was examined in 57 patients undergoing coronary artery bypass grafting (41 men and 16 women: 63.0 ± 10.6 years old) using two-dimensional transesophageal echocardiography. An intraaortic balloon pump (IABP) was instituted in ten patients. A short-axis view of DTA was examined for intraluminal projection from the diaphragm level to the aortic arch level. In a frozen-frame image, the area and the height of the projection at each clockwise direction was measured. Four patients with preoperative insertion of an IABP catheter were excluded from the analysis. Seventy projections were found in 40 of 53 patients (75.5%), most frequently found at the 3 to 6 o'clock position. The tip of the IABP catheter was also located in the area between 3 and 6 o'clock of the aortic lumen in 6 of 10 patients. In one case, the area of projection was reduced from 1.1 cm2 to 0.7 cm2. In two of four patients with preoperative institution of an IABP catheter, projections were found near the catheter tip.
Both intraluminal projections and IABP catheter tip were most commonly located in the same region of the DTA, suggesting a possible dislodging of the projection while advancing the catheter. This was demonstrated in one case. The catheter tip may damage the aortic intima and/or cause a formation of abnormal projection. We conclude that intraoperative examination of DTA in addition to routine monitoring can provide useful information which is helpful for minimizing complications at the time of insertion of an IABP catheter. |
著者キーワード |
Aorta
Transesophageal echocardiography (TEE)
Intraaortic balloon pump (IABP)
|
NDC分類 |
医学 [ 490 ]
|
言語 |
英語
|
資源タイプ | 紀要論文 |
出版者 |
Hiroshima University Medical Press
|
発行日 | 1991-12 |
出版タイプ | Version of Record(出版社版。早期公開を含む) |
アクセス権 | オープンアクセス |
収録物識別子 |
[ISSN] 0018-2052
[NCID] AA00664312
[PMID] 1797742
|