Indoor Air Quality and Ventilation Strategies in the Use of Combustion Space Heating Appliances in Housing
Hiroshima Journal of Medical Sciences 43 巻 4 号
163-167 頁
1994-12 発行
アクセス数 : 761 件
ダウンロード数 : 109 件
今月のアクセス数 : 3 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00037895
ファイル情報(添付) |
HiroshimaJMedSci_43_163.pdf
440 KB
種類 :
全文
|
タイトル ( eng ) |
Indoor Air Quality and Ventilation Strategies in the Use of Combustion Space Heating Appliances in Housing
|
作成者 |
Setiani Onny
|
収録物名 |
Hiroshima Journal of Medical Sciences
|
巻 | 43 |
号 | 4 |
開始ページ | 163 |
終了ページ | 167 |
収録物識別子 |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
抄録 |
Indoor air quality (IAQ) in the use of combustion appliances is important for adequate evaluation of air pollution health risks. Since people spend most of their time inside buildings, especially the elderly and children, their exposure to indoor air contaminants can increase health problems in the community. Combustion materials emitted from combustion space heating appliances in housing during the winter may become a serious problem to health, since sources of ventilation are usually left closed to obtain a comfortable temperature level. To evaluate the IAQ and factors that may decrease combustion materials emitted from heaters, a study was done by using a house exposure model. The study found that IAQ in an unventilated house during combustion heater use was poor due to lack of fresh air. When using a heater, natural ventilation should be used to dilute air contaminants emitted from the heater. A concentration of carbon dioxide at about 1000 ppm and a comfortable temperature of 20°C could be maintained by applying natural ventilation of about 0.12 m^2 during the use of an unvented kerosene space heater. However, ventilation also depends on the number of the occupants and the wind velocity. The use of a steamer is also important to provide optimum humidity levels without elevating the respirable dust concentration above the acceptable limit.
|
著者キーワード |
Indoor air quality (IAQ)
Combustion materials
Natural ventilation
Humidification
|
NDC分類 |
医学 [ 490 ]
|
言語 |
英語
|
資源タイプ | 紀要論文 |
出版者 |
Hiroshima University Medical Press
|
発行日 | 1994-12 |
出版タイプ | Version of Record(出版社版。早期公開を含む) |
アクセス権 | オープンアクセス |
収録物識別子 |
[ISSN] 0018-2052
[NCID] AA00664312
|