Effectiveness of Assistance Circulations for Distal Circulatory Support during Cross-clamping of the Descending Thoracic Aorta
Hiroshima Journal of Medical Sciences 43 巻 4 号
135-144 頁
1994-12 発行
アクセス数 : 798 件
ダウンロード数 : 94 件
今月のアクセス数 : 3 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00037892
ファイル情報(添付) |
HiroshimaJMedSci_43_135.pdf
1.07 MB
種類 :
全文
|
タイトル ( eng ) |
Effectiveness of Assistance Circulations for Distal Circulatory Support during Cross-clamping of the Descending Thoracic Aorta
|
作成者 |
Liu Gang
|
収録物名 |
Hiroshima Journal of Medical Sciences
|
巻 | 43 |
号 | 4 |
開始ページ | 135 |
終了ページ | 144 |
収録物識別子 |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
抄録 |
In order to find the ideal distal circulatory support during cross-clamping of the descending thoracic aorta, the author compared the effects of simple shunting (SS) and centrifugal pump (CP) on hemodynamics and metabolisms in mongrel dogs. In group I (control), the aorta was cross-clamped for two hours without SS or CP; in group II (SS), a temporary shunt was placed between the left common carotid and left femoral arteries during cross-clamping; in group III (CP), with left heart bypass, the flow was maintained about the same as that in group II; in group IV (CP), proximal pressure was maintained unchanged. Hemodynamic and metabolic parameters were recorded prior to cross-clamping and every 30 min for four hours during and after cross-clamping. All animals in group I suffered from hemodynamic instability, metabolic abnormalities and neurologic injury and died within 12 hours. Hemodynamic changes were more unstable in group III than in groups II and IV. Three dogs in group III and also in group IV but none in group II, suffered from neurologic injury. Metabolic changes in groups II, III and IV were not significant. The author conclude that hemodynamic and metabolic abnormalities can be minimized through the efficient use of a shunt in cross-clamping of the descending thoracic aorta and postoperative complications such as paraplegia, renal failure and hepatic dysfunction can be prevented. The centrifugal pump as a distal circulatory support device is able to maintain stable hemodynamics and normal distal organic metabolisms if aortic pressure proximal to the clamp is maintained essentially unchanged through regulation of pump flow. However, it is unable to prevent paraplegia during cross-clamping of the descending thoracic aorta for two hours. Shortening the time of cross-clamping of the descending thoracic aorta is necessary to prevent paraplegia.
|
著者キーワード |
Aorta
Clamp
Shunt
|
NDC分類 |
医学 [ 490 ]
|
言語 |
英語
|
資源タイプ | 紀要論文 |
出版者 |
Hiroshima University Medical Press
|
発行日 | 1994-12 |
出版タイプ | Version of Record(出版社版。早期公開を含む) |
アクセス権 | オープンアクセス |
収録物識別子 |
[ISSN] 0018-2052