High-voltage testing of a 500-kV dc photocathode electron gun
Review of Scientific Instruments Volume 81 Issue 3
published_at 2010
アクセス数 : 912 件
ダウンロード数 : 333 件
今月のアクセス数 : 5 件
今月のダウンロード数 : 3 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00030122
File |
RevSciInstrum_81_033304.pdf
2.21 MB
種類 :
fulltext
|
Title ( eng ) |
High-voltage testing of a 500-kV dc photocathode electron gun
|
Creator |
Nagai Ryoji
Hajima Ryoichi
Nishimori Nobuyuki
Muto Toshiya
Yamamoto Masahiro
Honda Yosuke
Miyajima Tsukasa
Iijima Hokuto
Kuwahara Makoto
Okumi Shoji
Nakanishi Tsutomu
|
Source Title |
Review of Scientific Instruments
|
Volume | 81 |
Issue | 3 |
Abstract |
A high-voltage dc photocathode electron gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The dc photocathode electron gun is designed for future light sources based on energy-recovery linac and consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The segmented cylindrical ceramic insulator and the guard-ring electrodes were utilized to prevent any damage to the insulator from electrons emitted by the support-rod electrode.
|
Keywords |
ceramic insulators
electron guns
photocathodes
|
NDC |
Electrical engineering [ 540 ]
|
Language |
eng
|
Resource Type | journal article |
Publisher |
American Institute of Physics
|
Date of Issued | 2010 |
Rights |
Copyright 2010 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.
|
Publish Type | Version of Record |
Access Rights | open access |
Source Identifier |
[ISSN] 0034-6748
[DOI] 10.1063/1.3354980
[NCID] AA00817730
[URI] http://link.aip.org/link/?rsi/81/033304