タイトル ( eng )
Living cell positioning on the surface of gold film for SPR analysis
作成者
Yanase Yuhki
Suzuki Hidenori
Tsutsui Tomoko
Uechi Ichiro
Mihara Shoji
収録物名
Biosensors & Bioelectronics
23
4
開始ページ 562
終了ページ 567
抄録
Living cell reactions are detected as changes of the angle of resonance (AR) for surface plasmon resonance (SPR). Since SPR reflects the events in the field of evanescence, cells need to be fixed on the sensor chip. In this study, we developed methods to fix living cells on a gold surface and to recover adherent cells from the culture dish, preserving their functions to be analyzed by SPR. Human basophils and B cells were fixed to the sensor chip by a biocompatible anchor for cell membranes (alpha-succinimidyloxysuccinyl omega-oleyloxy polyoxyethylene), aminoalkanethiol (cyteamine, 8-amino octanethiol) or an amino-reactive cross-linker (dithiobis [succinimidylpropionate]). They showed an increase of AR in response to various stimuli. RBL-2H3 cells, which firmly adhered to the culture dish, were cultured/recovered with HydroCelI(TM)/Simple pipetting, with RepCelI(TM)/pipetting at 4 degrees C, or on normal plastic culture dishes with trypsinization or by scraping at 4 degrees C, respectively. The exocytosis of RBL-2H3 cells was largely impaired by scraping, but only slightly by the treatment with pipetting on HydroCell(TM), on RepCell(TM) or with trypsin. The membrane ruffling of the cells prepared by the last three treatments induced by antigens appeared the same. However, the change of AR with cells prepared by trypsin and those by scraping at 4 degrees C were lower than those by HydroCell(TM) or RepCell(TM), suggesting that trypsin may harm molecules involved in cellular reactions. Thus, the methods of cell fixation and removal with HydroCell(TM) or RepCell(TM) should enable us to analyze various reactions in either adherent or non-adherent cells by SPR.
著者キーワード
biosensor
surface plasmon resonance
non-adherent cells
cell fixation
recovery
NDC分類
医学 [ 490 ]
言語
英語
資源タイプ 学術雑誌論文
出版者
Elsevier Advanced Technology
発行日 2007-11
権利情報
Copyright(c) 2007 Elsevier Advanced Technology
出版タイプ Author’s Original(十分な品質であるとして、著者から正式な査読に提出される版)
アクセス権 オープンアクセス
収録物識別子
[ISSN] 0956-5663
[DOI] 10.1016/j.bios.2007.07.005
[NCID] AA10739666
[DOI] http://dx.doi.org/10.1016/j.bios.2007.07.005 ~の異版である