Reconstruction of Pterional Key Hole Using Three-dimensional Titanium Plate : Technical Note

アクセス数 : 1113
ダウンロード数 : 130

今月のアクセス数 : 14
今月のダウンロード数 : 5
File
KJ00004161821.pdf 1.71 MB 種類 : fulltext
Title ( eng )
Reconstruction of Pterional Key Hole Using Three-dimensional Titanium Plate : Technical Note
Creator
Sadatomo Takashi
Yuki Kiyoshi
Migita Keisuke
Taniguchi Eiji
Kodama Yasunori
Source Title
Hiroshima Journal of Medical Sciences
Volume 54
Issue 2
Start Page 53
End Page 56
Journal Identifire
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
Abstract
Patients who have undergone pterional craniotomy sometimes complain about postoperative cosmetic impairment in the frontotemporal area. This problem occurs as a result of inappropriate repair or no repair of the pterional key hole. The authors have developed an intraoperative hand-made three-dimensional titanium plate, and as a result of using this plate the postoperative cosmetic appearance was satisfactory.
Keywords
Aneurysm
Pterional approach
Cosmetic appearance
NDC
Medical sciences [ 490 ]
Language
eng
Resource Type departmental bulletin paper
Publisher
Hiroshima University Medical Press
国立情報学研究所
Date of Issued 2005-06
Publish Type Version of Record
Access Rights open access
Source Identifier
[ISSN] 0018-2052
[NCID] AA00664312