Electron Beam CT versus 16-slice Spiral CT : How Accurately Can We Measure Coronary Artery Calcium Volume?
European Radiology 16 巻 2 号
374-380 頁
2006-02 発行
アクセス数 : 701 件
ダウンロード数 : 188 件
今月のアクセス数 : 3 件
今月のダウンロード数 : 1 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00017068
ファイル情報(添付) |
EuroRadiol_16_374.pdf
760 KB
種類 :
全文
|
タイトル ( eng ) |
Electron Beam CT versus 16-slice Spiral CT : How Accurately Can We Measure Coronary Artery Calcium Volume?
|
作成者 |
Horiguchi Jun
Shen Yun
Akiyama Yuuji
Hirai Nobuhiko
Sasaki Kosuke
Ishifuro Minoru
Ito Katsuhide
|
収録物名 |
European Radiology
|
巻 | 16 |
号 | 2 |
開始ページ | 374 |
終了ページ | 380 |
抄録 |
Objective: The purpose of this study is to investigate how accurately we can measure CAC volume using electron beam computed tomography (CT) and 16-slice spiral CT. Materials and Methods: CAC models with known volume attached to a cardiac phantom were scanned. The error of measurement, variability between measured and real volumes and inter-scan measurement variability were obtained. For spiral CT, 7 different parameters; i.e. (1) slice-thickness (0.625mm, 1.25mm and 2.5mm), (2) retrospective spiral electrocardiograph (ECG)-gated or prospective axial ECG-triggering, (3) overlapping or non-overlapping, were included. Results: The error of measurement was 150n electron beam CT and 8-2027777735740n spiral CT. CAC volumes were underestimated in 92-0x1.4b3a0b6a4aap-149nd overestimated in 81024570420f the electron beam CT scans. Volumes were underestimated in 79%, correct in 5-0x1.86278bfffa1a8p-150nd overestimated in 1626651131640f the spiral CT scans. The best measurement and the least variability was observed on 0.625mm retrospective spiral ECG-gated CT (error of 8%), a significant result (t-test: p<0.01) when compared with electron beam CT. Conclusion: CAC volume measurement on CT scanners may be significantly different and often underestimates the real volume of CAC. For precise evaluation of CAC volume, thin-slice retrospective spiral ECG-gated scan using a spiral CT scanner is desirable.
|
著者キーワード |
Calcification
Coronary artery
Electron beam CT
Spiral CT
|
NDC分類 |
医学 [ 490 ]
|
言語 |
英語
|
資源タイプ | 学術雑誌論文 |
出版者 |
Springer
|
発行日 | 2006-02 |
権利情報 |
Copyright (c) 2006 Springer-Verlag. "The original publication is available at www.springerlink.com"
|
出版タイプ | Author’s Original(十分な品質であるとして、著者から正式な査読に提出される版) |
アクセス権 | オープンアクセス |
収録物識別子 |
[ISSN] 0938-7994
[DOI] 10.1007/s00330-005-2904-9
[NCID] AA10824302
[PMID] 16175352
[DOI] http://dx.doi.org/10.1007/s00330-005-2904-9
~の異版である
|