Electron Beam CT versus 16-slice Spiral CT : How Accurately Can We Measure Coronary Artery Calcium Volume?

European Radiology Volume 16 Issue 2 Page 374-380 published_at 2006-02
アクセス数 : 667
ダウンロード数 : 173

今月のアクセス数 : 11
今月のダウンロード数 : 5
File
EuroRadiol_16_374.pdf 760 KB 種類 : fulltext
Title ( eng )
Electron Beam CT versus 16-slice Spiral CT : How Accurately Can We Measure Coronary Artery Calcium Volume?
Creator
Horiguchi Jun
Shen Yun
Akiyama Yuuji
Hirai Nobuhiko
Sasaki Kosuke
Ishifuro Minoru
Ito Katsuhide
Source Title
European Radiology
Volume 16
Issue 2
Start Page 374
End Page 380
Abstract
Objective: The purpose of this study is to investigate how accurately we can measure CAC volume using electron beam computed tomography (CT) and 16-slice spiral CT. Materials and Methods: CAC models with known volume attached to a cardiac phantom were scanned. The error of measurement, variability between measured and real volumes and inter-scan measurement variability were obtained. For spiral CT, 7 different parameters; i.e. (1) slice-thickness (0.625mm, 1.25mm and 2.5mm), (2) retrospective spiral electrocardiograph (ECG)-gated or prospective axial ECG-triggering, (3) overlapping or non-overlapping, were included. Results: The error of measurement was 150n electron beam CT and 8-2027777735740n spiral CT. CAC volumes were underestimated in 92-0x1.4b3a0b6a4aap-149nd overestimated in 81024570420f the electron beam CT scans. Volumes were underestimated in 79%, correct in 5-0x1.86278bfffa1a8p-150nd overestimated in 1626651131640f the spiral CT scans. The best measurement and the least variability was observed on 0.625mm retrospective spiral ECG-gated CT (error of 8%), a significant result (t-test: p<0.01) when compared with electron beam CT. Conclusion: CAC volume measurement on CT scanners may be significantly different and often underestimates the real volume of CAC. For precise evaluation of CAC volume, thin-slice retrospective spiral ECG-gated scan using a spiral CT scanner is desirable.
Keywords
Calcification
Coronary artery
Electron beam CT
Spiral CT
NDC
Medical sciences [ 490 ]
Language
eng
Resource Type journal article
Publisher
Springer
Date of Issued 2006-02
Rights
Copyright (c) 2006 Springer-Verlag. "The original publication is available at www.springerlink.com"
Publish Type Author’s Original
Access Rights open access
Source Identifier
[ISSN] 0938-7994
[DOI] 10.1007/s00330-005-2904-9
[NCID] AA10824302
[PMID] 16175352
[DOI] http://dx.doi.org/10.1007/s00330-005-2904-9 isVersionOf