放射光を用いたEXAFS法によるSi-Ge合金の研究

アクセス数 : 777
ダウンロード数 : 124

今月のアクセス数 : 1
今月のダウンロード数 : 0
File
diss_otsu1773.pdf 2.55 MB 種類 : fulltext
Title ( eng )
放射光を用いたEXAFS法によるSi-Ge合金の研究
Title ( jpn )
Extended X-ray Absorption Fine Structure Studies of Si-Ge Alloys with Synchrotron Radiation
Creator
Kajiyama Hiroshi
Abstract
Extended X-ray absorption fine structure (EXAFS) has been developed to a useful tool for determining the local bonding structure around an X-ray absorbing atom.EXAFS spectra are usually interpreted by a simple formula derived from an electron scattering theory, with the plane wave approximation. A curve-fitting technique gives plausible bond lengths, where the absorbing edge energy, E₀, is used as one of the parameters. Model compounds are necessary to get the reliable structure in most cases. However, in the case of binary or ternary compounds, it is unreasonable to yield different values of E₀ for different neighboring atoms through the curve-fitting procedure. Furthermore, it is difficult to find good model compounds.

A new method has been developed here tor the EXAFS analysis, which is based on the spherical wave approach for emitted electrons. This method is proved to give a reliable structure even without model compounds. Ge K-edge EXAFS spectra have been measured for amorphous-Si₁-xGex:H (x=0.27, 0.36, 0.38, o.47, 0.56, 1.0) and crystalline-Si₁-xGex (x=0.2, 0.39, 0.59, 0.81, 1.0), using synchrotron radiation as the photon source.Spectra were analyzed by the newly developed method without using model compounds and by fixing the E₀ value at the steepest point of the absorption edge.

Obtained results show that Ge-Ge and Ge-Si bond lengths of amorphous- Si₁-xGex:H are 2.46Å and 2.41Å, respectively, irrespective of Ge concentration. These bond lengths can be interpreted by the sum of the atomic radii of constituent elements as pointed by Bragg and later by Pauling. As for the case of crystalline-Si₁-xGex, the resulted bond lengths of Ge-Ge and Ge-Si were almost similar to the corresponding bond lengths in amorphous-Si₁-xGex:H. The difference of crystalline and amorphous alloys should be only interpreted by the difference of bond angle distortion. A study on the coordination around a Ge atom in amorphous-Si₁-xGe:H revealed that Ge and Si atoms are randomly mixed in the compositional range below 40 atomic percent. In the amorphous alloys with higher Ge content, the coodinations of Ge atoms surrounding a central Ge atoms is 15-20 percent higher than expected for a random mixture, suggesting a structural inhomogeneity in Ge-rich region. Whereas in crystalline Si₁-xGex, it is found that Ge and Si atoms are randomly mixed in the studied compositional range.
NDC
Metal and mining engineering [ 560 ]
Language
eng
Resource Type doctoral thesis
Rights
Copyright(c) by Author
Access Rights open access
Dissertation Number 乙第1773号
Degree Name
Date of Granted 1988-11-28
Degree Grantors
広島大学