Computed Tomography Fluoroscopy-guided Biopsy of Lung Nodules: Comparison of the Step-wise and Realtime Techniques
Hiroshima Journal of Medical Sciences Volume 70 Issue 2-4
Page 35-38
published_at 2021-12
アクセス数 : 322 件
ダウンロード数 : 63 件
今月のアクセス数 : 8 件
今月のダウンロード数 : 2 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00051912
File |
HiroshimaJMedSci_70_35.pdf
421 KB
種類 :
fulltext
|
Title ( eng ) |
Computed Tomography Fluoroscopy-guided Biopsy of Lung Nodules: Comparison of the Step-wise and Realtime Techniques
|
Creator |
KAJIWARA Kenji
MURAKAMI Kaho
MAEDA Hitomi
YOSHIMATSU Rika
YAMANISHI Tomoaki
MINAMIGUCHI Hiroki
YAMAGAMI Takuji
|
Source Title |
Hiroshima Journal of Medical Sciences
|
Volume | 70 |
Issue | 2-4 |
Start Page | 35 |
End Page | 38 |
Journal Identifire |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
Abstract |
The present study aimed to compare the step-wise and real-time techniques for computed tomography (CT) fluoroscopy-guided biopsy of lung nodules. It included 72 consecutive patients (50 men, 22 women; mean age: 71.8 years; range: 45–89 years) with lung nodules. Between March 2017 and April 2019, 72 CT fluoroscopy-guided biopsy procedures were performed using either the step-wise (n = 34) or real-time technique (n = 38). The diagnostic accuracy was 97.1% for biopsies performed using the step-wise technique and 94.7% for those performed using the real-time technique (p = 0.39). The mean CT dose index was 48.8 ± 16.9 mGy/s for the step-wise method and 59.9 ± 25.6 mGy/s for the real-time method; the dose length product was 1956 ± 729 mGy and 2613 ± 1300 mGy for the two techniques, respectively (p < 0.05). There was a significant difference in mean exposure time (81 ± 43 s for the step-wise technique and 162 ± 120 s for the real-time technique; p < 0.05). The mean lung nodule size was also significantly different (29.9 ± 17.6 mm for the step-wise method and 17.8 ± 12.2 mm for the real-time method; p < 0.01). Of the 34 step-wise procedures, 11 (32.4%) resulted in pneumothorax, as did 24 of 38 (63.2%) real-time procedures (p < 0.01). The real-time technique is particularly useful in patients with small nodules. The CT dose, exposure time, and incidence of pneumothorax were significantly lower when the step-wise technique was applied to CT fluoroscopy-guided biopsy of lung nodules.
|
Keywords |
Non-vascular intervention
Lung biopsy
CT fluoroscopy
Step-wise technique
|
Language |
eng
|
Resource Type | departmental bulletin paper |
Publisher |
Hiroshima University Medical Press
|
Date of Issued | 2021-12 |
Rights |
Copyright (c) 2021 Hiroshima University Medical Press
|
Publish Type | Version of Record |
Access Rights | open access |
Source Identifier |
[ISSN] 0018-2052
[ISSN] 2433-7668
[NCID] AA00664312
[DOI] 10.24811/hjms.70.2-4_35
[DOI] https://doi.org/10.24811/hjms.70.2-4_35
|