Image synthesis of monoenergetic CT image in dual-energy CT using kilovoltage CT with deep convolutional generative adversarial networks
Journal of Applied Clinical Medical Physics Volume 22 Issue 4
Page 184-192
published_at 2021-04-10
アクセス数 : 528 件
ダウンロード数 : 133 件
今月のアクセス数 : 0 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00051051
File | |
Title ( eng ) |
Image synthesis of monoenergetic CT image in dual-energy CT using kilovoltage CT with deep convolutional generative adversarial networks
|
Creator | |
Source Title |
Journal of Applied Clinical Medical Physics
|
Volume | 22 |
Issue | 4 |
Start Page | 184 |
End Page | 192 |
Abstract |
Purpose: To synthesize a dual-energy computed tomography (DECT) image from an equivalent kilovoltage computed tomography (kV-CT) image using a deep convolutional adversarial network.
Methods: A total of 18,084 images of 28 patients are categorized into training and test datasets. Monoenergetic CT images at 40, 70, and 140 keV and equivalent kVCT images at 120 kVp are reconstructed via DECT and are defined as the reference images. An image prediction framework is created to generate monoenergetic computed tomography (CT) images from kV-CT images. The accuracy of the images generated by the CNN model is determined by evaluating the mean absolute error (MAE), mean square error (MSE), relative root mean square error (RMSE), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and mutual information between the synthesized and reference monochromatic CT images. Moreover, the pixel values between the synthetic and reference images are measured and compared using a manually drawn region of interest (ROI). Results: The difference in the monoenergetic CT numbers of the ROIs between the synthetic and reference monoenergetic CT images is within the standard deviation values. The MAE, MSE, RMSE, and SSIM are the smallest for the image conversion of 120 kVp to 140 keV. The PSNR is the smallest and the MI is the largest for the synthetic 70 keV image. Conclusions: The proposed model can act as a suitable alternative to the existing methods for the reconstruction of monoenergetic CT images in DECT from single-energy CT images. |
Keywords |
deep learning
artificial Intelligence
dual-energy CT
image synthesis
|
Language |
eng
|
Resource Type | journal article |
Publisher |
Wiley Periodicals, Inc.
American Association of Physicists in Medicine
|
Date of Issued | 2021-04-10 |
Rights |
© 2021 The Authors. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
|
Publish Type | Version of Record |
Access Rights | open access |
Source Identifier |
[ISSN] 1526-9914
[DOI] 10.1002/acm2.13190
[PMID] 33599386