Assessment of biological dosimetric margin for stereotactic body radiation therapy
Journal of Applied Clinical Medical Physics Volume 21 Issue 4
Page 31-41
published_at 2020-04-20
アクセス数 : 329 件
ダウンロード数 : 76 件
今月のアクセス数 : 11 件
今月のダウンロード数 : 4 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00050436
File |
JApplClinMedPhys_21_31.pdf
1.31 MB
種類 :
fulltext
|
Title ( eng ) |
Assessment of biological dosimetric margin for stereotactic body radiation therapy
|
Creator |
Ozawa Shuichi
Shiinoki Takehiro
Tsubouchi Kento
|
Source Title |
Journal of Applied Clinical Medical Physics
|
Volume | 21 |
Issue | 4 |
Start Page | 31 |
End Page | 41 |
Abstract |
Purpose: To develop a novel biological dosimetric margin (BDM) and to create a biological conversion factor (BCF) that compensates for the difference between physical dosimetric margin (PDM) and BDM, which provides a novel scheme of a direct estimation of the BDM from the physical dose (PD) distribution.
Methods: The offset to isocenter was applied in 1‐mm steps along left‐right (LR), anterior‐posterior (AP), and cranio‐caudal (CC) directions for 10 treatment plans of lung stereotactic body radiation therapy (SBRT) with a prescribed dose of 48 Gy. These plans were recalculated to biological equivalent dose (BED) by the linearquadratic model for the dose per fraction (DPF) of d = 3–20 Gy/fr and α/β= 3 - 10. BDM and PDM were defined so that the region that satisfied that the dose covering 95% (or 98%) of the clinical target volume was greater than or equal to the 90% of the prescribed PD and BED, respectively. An empirical formula of the BCF was created as a function of the DPF. Results: There was no significant difference between LR and AP directions for neither the PDM nor BDM. On the other hand, BDM and PDM in the CC direction were significantly larger than in the other directions. BCFs of D95% and D98% were derived for the transverse (LR and AP) and longitudinal (CC) directions. Conclusions: A novel scheme to directly estimate the BDM using the BCF was developed. This technique is expected to enable the BED‐based SBRT treatment planning using PD‐based treatment planning systems. |
Keywords |
biological equivalent dose
dosimetric margin
LQ model
SBRT
|
Language |
eng
|
Resource Type | journal article |
Publisher |
American Association of Physicists in Medicine
Wiley
|
Date of Issued | 2020-04-20 |
Rights |
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
|
Publish Type | Version of Record |
Access Rights | open access |
Source Identifier |
[ISSN] 1526-9914
[DOI] 10.1002/acm2.12843
[PMID] 32141684