Flow Chemiluminescence Determination of Antimony(III,V) Using a Rhodamine B-Cetyltrimethylammonium Chloride Reversed Micelle System Following Liquid–Liquid Extraction
Analytical Sciences Volume 29 Issue 1
Page 73-77
published_at 2013-01
アクセス数 : 602 件
ダウンロード数 : 146 件
今月のアクセス数 : 4 件
今月のダウンロード数 : 3 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00047037
File |
AnalySci_29_73.pdf
435 KB
種類 :
fulltext
|
Title ( eng ) |
Flow Chemiluminescence Determination of Antimony(III,V) Using a Rhodamine B-Cetyltrimethylammonium Chloride Reversed Micelle System Following Liquid–Liquid Extraction
|
Creator |
Yamamoto Tomoyuki
Tsunemine Yusuke
Hayakawa Fumio
Hasanin Tamer H. A.
|
Source Title |
Analytical Sciences
|
Volume | 29 |
Issue | 1 |
Start Page | 73 |
End Page | 77 |
Abstract |
A flow chemiluminescence (CL) method combined with a liquid–liquid extraction technique is proposed for the indirect determination of antimony in aqueous samples using rhodamine B (RB). In the liquid–liquid extraction process, the antimony(V) chloro-complex anion, [SbCl6]−, was extracted from an aqueous acidic solution into toluene via ion-pair formation with the protonated RBH+ ion. Upon mixing the extract with a reversed micellar reagent solution of cetyltrimethylammonium chloride (CTAC) in 1-hexanol–cyclohexane/water (0.60 mol dm−3 H2SO4) containing cerium(IV), uptake of the ion-pair by CTAC reversed micelles occurred easily, followed by an oxidation reaction of RB with Ce(IV) in the CL process. The CL signal produced was then measured. Using a flow injection system, the detection limits (DL) of 0.25 μmol dm−3 Sb(III) and 0.20 μmol dm−3 Sb(V), and linear calibration graphs with dynamic ranges from the respective DLs to 16 μmol dm−3 for Sb(III) and Sb(V) were obtained under optimized experimental conditions. The proposed method was successfully applied to a mixture of Sb(III) and Sb(V), where total antimony, Sb(III) + Sb(V), was measured using ceric sulfate as an oxidant to oxidize Sb(III) to Sb(V) prior to extraction, Sb(V) was determined directly without the use of an oxidant, and Sb(III) was calculated by difference.
|
Descriptions |
This work was partially supported by a Grant-in-Aid for Scientific Research, No. 23550097, from the Ministry of Education, Science, Sports, and Culture, Japan.
|
NDC |
Chemistry [ 430 ]
|
Language |
eng
|
Resource Type | journal article |
Publisher |
The Japan Society for Analytical Chemistry
|
Date of Issued | 2013-01 |
Rights |
2013 © The Japan Society for Analytical Chemistry
|
Publish Type | Version of Record |
Access Rights | open access |
Source Identifier |
[ISSN] 0910-6340
[ISSN] 1348-2246
[NCID] AA10500785
[DOI] 10.2116/analsci.29.73
[DOI] https://doi.org/10.2116/analsci.29.73
|