Ammonia Removal by Air Stripping Tower

アクセス数 : 1081
ダウンロード数 : 1810

今月のアクセス数 : 4
今月のダウンロード数 : 6
File
HiroshimaJMedSci_33_639.pdf 278 KB 種類 : fulltext
Title ( eng )
Ammonia Removal by Air Stripping Tower
Title ( jpn )
エアーストリップ法によるアンモニア除去装置
Creator
Kawanishi Hideki
Nishiki Masayuki
Sugiyama Masafumi
Tsuchiya Taro
Ezaki Haruo
Source Title
Hiroshima Journal of Medical Sciences
Volume 33
Issue 4
Start Page 639
End Page 642
Journal Identifire
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
Abstract
Ammonia is a very soluble gas in water. The stage of NH3 and NH4+ is affected by pH and temperature. This study reports an ammonia removal by an air stripping tower which is filled up with packing bed (Intalox Saddles). This tower is an apparatus that removes only isolated NH3 by air stripping. In vitro removal, the study has revealed that the ammonia removal ratios are 97.3, 95.3, 95.0 and 91.5% when the flow rates of each test solution are 100, 200 and 300 ml/min. at the condition of pH 11.0. It also revealed that the ammonia removal rates were more than 90% without regard to the test solution's initial concentration at pH 11.0 at the flow rate of 100 ml/min. At pH 9.0, it revealed only 18% removal rate. Each result agrees with the theoretical values of ammonia in water. These studies suggest that our ammonia removal system is effective in artificial kidney with dialysate regeneration.
Keywords
Ammonia
Urea
Air stripping
Urease
Artificial kidney
NDC
Medical sciences [ 490 ]
Language
eng
Resource Type departmental bulletin paper
Publisher
Hiroshima University School of Medicine
Date of Issued 1984-12
Publish Type Version of Record
Access Rights open access
Source Identifier
[ISSN] 0018-2052
[NCID] AA00664312
[PMID] 6534920