Comparison of Properties of Slow Pathway Potential between Successful and Unsuccessful Radiofrequency Applications in Patients who Underwent Catheter Ablation for Atrioventricular Nodal Reentrant Tachycardia

アクセス数 : 927
ダウンロード数 : 207

今月のアクセス数 : 0
今月のダウンロード数 : 0
ファイル情報(添付)
HiroshimaJMedSci_49_15.pdf 1.47 MB 種類 : 全文
タイトル ( eng )
Comparison of Properties of Slow Pathway Potential between Successful and Unsuccessful Radiofrequency Applications in Patients who Underwent Catheter Ablation for Atrioventricular Nodal Reentrant Tachycardia
作成者
Hirao Hidekazu
Muraoka Yuji
Yamagata Togo
Matsuura Hideo
Kajiyama Goro
収録物名
Hiroshima Journal of Medical Sciences
49
1
開始ページ 15
終了ページ 27
収録物識別子
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
抄録
Findings concerning selective slow pathway radiofrequency ablation for atrioventricular nodal reentrant tachycardia (A VNRT) using the slow pathway potential (SPP) guided method are reported. The electrogram at the SPP recording site showed double potentials consisting of the atrial potential (A) and SPP. However, SPP is usually recorded widely in the right atrial posteroseptal region. To examine whether there was any characteristic marker in the electrogram at the SPP recording site specific to successful RF application, the properties of SPP and its anatomical locations in both successful (S) (38 sites) and unsuccessful (UN) (28 sites) application sites were analyzed in 38 patients who underwent SPP-guided ablation. The distance between the upper margin of the coronary sinus ostium (UCSO) and the ablation catheter (ABL) (DUCSO-ABL) was shorter in S than in UN (2.3 ± 6.3 mm vs. 9.0 ± 5.2 mm below the level of UCSO, p < 0.001). The interval between A and SPP (A-SPP) was longer in S than in UN (44.2 ± 9.9 msec vs. 24.0 ± 7.0 msec, p < 0.001). RF applications at the more anterior sites with longer A-SPP were more successful than at other sites. The sensitivity and specificity of A-SPP (more than 40 msec) were superior to those of DUCSO-ABL (within 5 mm) as the marker for the successful application (sensitivity; 73.7% v.s. 68.4%, specificity; 100% v.s. 82.1 %, respectively). In conclusion, the sites with longer A-SPP might be specific for successful ablation.
著者キーワード
Atrioventricular nodal reentrant tachycardia
Radiofrequency catheter ablation
Slow pathway potential
Upper margin of coronary sinus ostium
NDC分類
医学 [ 490 ]
言語
英語
資源タイプ 紀要論文
出版者
Hiroshima University Medical Press
発行日 2000-03
出版タイプ Version of Record(出版社版。早期公開を含む)
アクセス権 オープンアクセス
収録物識別子
[ISSN] 0018-2052
[NCID] AA00664312