An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR : A manikin study
Hiroshima Journal of Medical Sciences Volume 63 Issue 1-3
Page 7-11
published_at 2014-09
アクセス数 : 1367 件
ダウンロード数 : 211 件
今月のアクセス数 : 4 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00037108
File |
HiroshimaJMedSci_63_7.pdf
246 KB
種類 :
fulltext
|
Title ( eng ) |
An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR : A manikin study
|
Creator |
Ishikawa Masami
Oue Kana
Yoshinaka Taiga
|
Source Title |
Hiroshima Journal of Medical Sciences
|
Volume | 63 |
Issue | 1-3 |
Start Page | 7 |
End Page | 11 |
Journal Identifire |
[PISSN] 0018-2052
[EISSN] 2433-7668
[NCID] AA00664312
|
Abstract |
It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-second break between the sets. The percentage of compressions deeper than 5 cm at pace-110-g decreased significantly from 22.1 ± 4.7% in the first set to 16.7 ± 4.4%* in the second set (*p<0.05 vs. the first set). However, no significant differences were observed between the first and second sets at pace-100-g and pace-90-g. The results obtained for pace-110-g were compared in detail by gender. In the male group, the percentage of compressions deeper than 5 cm was 43.5 ± 7.5% in the first set, and this decreased significantly to 34.6 ± 7.6%* in the second set (*p<0.001 vs. the first set). However, the percentage of compressions deeper than 5 cm in the female group was 2.3 ± 1.6%* in the first set and 0.2 ± 0.2%* in the second set (*p<0.05 vs. male). Our study demonstrated that the compression pace of 110 compressions per min was inadequate to provide chest compressions of an appropriate depth, which decreased rapidly. Therefore, limiting the rate of compressions to within a certain number per min may contribute to minimizing deteriorations in compression depth in hands-only CPR.
|
Keywords |
Hands-only CPR
Chest compression
Compression pace
|
NDC |
Medical sciences [ 490 ]
|
Language |
eng
|
Resource Type | departmental bulletin paper |
Publisher |
Hiroshima University Medical Press
|
Date of Issued | 2014-09 |
Rights |
Copyright (c) Hiroshima University Medical Press
|
Publish Type | Version of Record |
Access Rights | open access |
Source Identifier |
[ISSN] 0018-2052