Monolithic silica capillary column as a new tool for extraction of methamphetamine in urine
Japanese journal of forensic toxicology 22 巻 3 号
200-204 頁
2004 発行
アクセス数 : 908 件
ダウンロード数 : 0 件
今月のアクセス数 : 3 件
今月のダウンロード数 : 0 件
この文献の参照には次のURLをご利用ください : https://ir.lib.hiroshima-u.ac.jp/00030119
タイトル ( eng ) |
Monolithic silica capillary column as a new tool for extraction of methamphetamine in urine
|
タイトル ( jpn ) |
モノリス型カラムを用いた尿中メタンフェタミンの抽出
|
作成者 |
Nakamoto Akihiro
Nishida Manami
Yashiki Mikio
Kuramoto Takako
Takei Yoshiyuki
Furuno Masahiro
Minakuchi Hiroyoshi
Nakanishi Kazuki
Kimura Kojiro
|
収録物名 |
Japanese journal of forensic toxicology
|
巻 | 22 |
号 | 3 |
開始ページ | 200 |
終了ページ | 204 |
抄録 |
We have established a simple screening method for methamphetamine (MA) in urine using a monolithic silica capillary column for extraction and using the Simon's reagent for colorimetric determination. Urine was mixed with borate buffer solution (50 mM, pH 10.2) and the mixture was passed through the column connected with the needle of a gas-tight syringe. MA in urine was adsorbed to the column, then eluted with 10 µl of ethyl acetate, and directly spotted on a thin-layer chromatographic plate by dividing the eluate into several aliquots. To separate MA from urine impurities and detect it clearly, a 2-µl volume of a solvent mixture (chloroform : methanol = 95 : 5, v/v, saturated with 28-0x1.fa060bfff8bbp+0mmonium hydroxide) was applied to the spot for concentrically development of the analyte.
After drying the solvent, 0.5% sodium nitroprusside solution containing 10% sodium carbonate was sprayed on the plate. The plate was put in a bottle saturated with acetaldehyde, and the ring was changed purple (Simon's reaction) when MA existed in urine. The macroscopic detection limit of MA in urine by this method was 0.5 µg/ml. To confirm efficiency of this method, the eluate from the column was analyzed by GC/MS using penta-deuterated MA as internal standard. By analysis of 30 urine samples, the results obtained by the present spot test agreed well with those by GC/MS. |
著者キーワード |
Methamphetamine
Monolithic silica capillary column
Solid-phase extraction
Spot test
Simon's reaction
|
NDC分類 |
医学 [ 490 ]
|
言語 |
英語
|
資源タイプ | 学術雑誌論文 |
出版者 |
Japanese Association of Forensic Toxicology
日本法中毒学会
|
発行日 | 2004 |
権利情報 |
(c) 2004 Japanese Association of Forensic Toxicology.
|
出版タイプ | Author’s Original(十分な品質であるとして、著者から正式な査読に提出される版) |
アクセス権 | メタデータのみ |
収録物識別子 |
[ISSN] 0915-9606
[URI] http://wwwsoc.nii.ac.jp/jaft/
|