Aim: Recent advances in three-dimensional imaging have led to an increased interest in the application of computer-models in paediatric dentistry. However, in evidence-based paediatric dentistry the accuracy of new methods must be validated before they are introduced to clinical practice. We aimed to compare the accuracy of measurements of digital models obtained using a noncontact 3D measuring system, with direct measurements made on plaster models (gold standard) from children.

Materials and methods: Twelve pairs of plaster models were obtained from children with deciduous dentition; tooth size, arch width, and arch length were examined. The same parts on each cast were measured twice with at least a 2-week interval between measurements with each method by four examiners. Linear mixed-effects model analyses were performed for comparison of values from the 2 different measurement methods.

Results: The average difference between the 2 methods in measured values, derived from the final model, was <0.2 mm. Random effect of examiners was always the smallest component of variance, and frequently negligible. Statistics: Intraclass correlation coefficients were typically >90%.

Conclusion: These results suggest that primary dentition analysis of digital models has a high accuracy level, comparable to that of direct measurement of plaster models by digital calipers.
掲載誌名
European Journal of Paediatric Dentistry
15巻
2号
開始ページ
137
終了ページ
142
出版年月日
2014-06
出版者
Italian Society of Paediatric Dentistry
ISSN
2035-648X
PubMedID
言語
英語
NII資源タイプ
学術雑誌論文
広大資料タイプ
学術雑誌論文
DCMIタイプ
text
フォーマット
application/pdf
著者版フラグ
publisher
部局名
病院