このエントリーをはてなブックマークに追加
ID 46726
本文ファイル
fig1-11.zip 877 KB
著者
Shiraishi, Masao
Murakami, Masahide
キーワード
Pulse tube
Flow visualization
Thermoacoustics
Fluid dynamics
NDC
化学
抄録(英)
The double-inlet pulse tube refrigerator that has a diaphragm inserted in a bypass-tube, which enabled it to transmit a pressure oscillation whereas to obstruct a DC gas flow, was manufactured and tested. The oscillating flow behavior inside of the refrigerator was studied by using a smoke-wire flow visualization technique. It was found that if the diaphragm was optimized, the performance would be improved more than that of the refrigerator with a bypass valve due to the increase in the PV work of the gas and the decrease in the convective heat loss caused by a secondary flow.
掲載誌名
Cryogenics
52巻
7-9号
開始ページ
410
終了ページ
415
出版年月日
2012
出版者
Elsevier Ltd.
ISSN
0011-2275
1879-2235
NCID
出版者DOI
言語
英語
NII資源タイプ
学術雑誌論文
広大資料タイプ
学術雑誌論文
DCMIタイプ
text
フォーマット
application/pdf
著者版フラグ
author
権利情報
Copyright (c) 2012 Elsevier Ltd.
This is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。
関連情報URL
部局名
先端物質科学研究科
備考
fig.1-11: Please see attached zip file.